RESPIREASY dedakj DE-2A Home Oxygen Concentrator Oxygen Therapy Instructions

                 

         RESPIREASY HOME OXYGEN CONCENTRATOR

                                   USER MANAUL

                                                         Model No.:DE-1LW
               In order to use this product safely, please read the user manual before use


BRAND INTRODUCTION 

RESPIREASYOxygen Concentrator is designed and manufactured by Shenzhen Jiaxing Technology Innovation Co., Ltd.

RESPIREASY, developed by Shenzhen Jiaxing Technology Innovation Co., Ltd., has specialized in oxygen concentrators for over 15 years. We provide 1–60 LPM portable, home, and medical-grade devices with original accessories, serving 400,000+ users in 60+ countries.

Germany R&D Based & Shenzhen Factory 

Backed by German respiratory experts in Germany R&D Based, we hold 100+ patents and focus on PSA efficiency, AI adaptive flow, and IoT monitoring. Our ISO 13485-certified Shenzhen factory (CE/ISO/NMPA) has a 2M annual capacity, with strict 7-step testing ensuring 93% purity and <0.5% failure rate in 2 years.

RESPIREASY delivers reliable, affordable, and smart oxygen therapy solutions for home, travel, and clinical care.

 

--RESPIREASY, easy respiratory care, smart oxygen therapy solutions

   

                           CONTENTS

                Safety precautions---------------------------------- 2
                Product features------------------------------------ 3
                Key technical indexes------------------------------- 3
                Installation and usage------------------------------ 4
               Care and maintenance------------------------------ 8
               Common trouble-shooting------------------------- 10
               Operation principle---------------------------------  12

                                                                       1

Safety precautions
In case of power outage and malfunction of theoxygen concentrator,an alternate source of supplemental oxygen (such as oxygen cylinder or oxygen bag)should be prepared for the user in urgent need of oxygen.The machine is not intended as medical device and is not tobe used for life support or life extension.

Pre-installation
Upside down operation is prohibited.
f the power supply has unstable voltage, or is beyond AC220+22(110+10)volt, please connect the voltage regulator before using the machine.Please use standard socket with  electrical safety qualifcation and terminal board with electricalsafety certifcation.

Laying Place
The machine should be located in a well-ventilated space and avoid direct sunlight. The distance between the machine and the wall or other objectsshould be no less than 10cm. Do not put other things or liquid vessel on themachine.
There should not be any obstruction around the airoutlet on the back and bottom of the machine,incase of air inlet and air outlet blocked, which couldlead to high temperature that will result in machine stoppage and decreasing of oxygen concentration.

Using
Oxygen is a combustion-supporting gas, so do not smoke and keep away from combustion source while using the machine for fear of fre accident. Do not switch on & off frequently. You can restart it after you have switched it off for 3-5 minutes, considering its service life. Avoid oil or grease-like material for any part of the machine. So as not to pollute the oxygen machine and cause fre.

                                                                      2

Product feature
The scope of product application: The product is designed in accordance with standard of Home personalusage appliance.
Health function:improved oxygen absorption can improvethe condition of the body to achieve the purpose of oxygen health care. Applicable to the elders, poor physique,pregnant women,students,and athletesr estore physical function

Function Feature
Intelligent control: LED display screen, easy use and operations operate for timing function.Overheat protection: the pure oil-free air compressor with overheat protector, will stop working automatically when the compressor's working temperature is too high to protect the compressor and the whole part of the product.

Operating principle
This product uses AC220V/110V as power source, air as raw material and adopts the pure oil-free air compressor and qualifed molecular sieve imported with original packaging, so as to generate high purity oxygen by PSAat normal temperate and supply oxygen.

Key Technical Indexes
Product name: Oxygen concentrator
Model: DE-2A
Oxygen generation method: Pressure Swing
Adsorption(PSA)
Rated voltage: AC220+22V 50+1Hz/AC110+10V 60Hz
Rated power: 200VA
Oxygen flow rate: 2L-9L/min adjustable
Oxygen concentration: 30%-90%(+3%) adjustable
Oxygen pressure:0.02-0.05MPa
Carbon dioxide: qualifed according to the specifed method
pH value: qualifed according to the method
Morphological identifcation: odorless,specifed colorless gas,combustion-support
Operating noise:≤45dB(A)
Classifcation:class II
Size:404mmx182mmx383mm
Net weight: 8.0kgDisplay control: LED light display, Intelligent chip control, infrared remote control

                                                                      3

Installation and Usage
Open-package inspection
After opening the package, please check whether the machine is in good
condition, and refer to the accessory list to ensure that it has included all of
the items,lf there is any missing item, please contact your supplier or
manufacturer in time for replacement.

Sketch Map
                                                                    4


Preparation Work

Filling water in humidifcation water tank: Grip the top handle of the humidifcation water tank by hand,pull out the water tank after pressing






Silicone plugs

Open silica gel plug at top and fll pure water to the highest water level line.
(Cool boiled water, distilled water and so on)*Do not exceed water level line






Make sure to cover the rubber plug before using,align the positioning groove at the bottom of water tank and then the outlet, put the humidifcation water tank back to the main body.












Connect oxygen tube: Connect one end of "Oxygen tube" with "oxygen outlet 
mouth",and connect the other end with oxygen
inhaler.








                                                                 5

Inhale Oxygen Operation

LED screen displayinstruction
1.Sleep function: The machine engage in sleep mode
automatically after running for 3 minutes,the screen
lights dimmed to power saving
2.Anion indicator
3. Cooling fan indicator
4. Timing setting indicator
5. Generating oxygen indicator
6. Cumulative time indicator






1.Electricity
When the oxygen machine is power on,open the power switch on the shell, the buzzer sounds for a long time, then LED screen light.

2.Power on
Press the key" generate oxygen",the machin ewill start, open the cooling fan,timing setting function,generate oxygen function,Cumulative time function and brand logo light synchronously, there is LED display light and blue light in water tank.

3.Timing +
Lightly touch the "Timing+" key, the timing is set to be 15 minutes.The timing setting is one-way circulation setting.The highest value is 180 minutes;3 seconds after you have done the timing operation,the timer will start into a countdown process.The operation of the "Timing-" key is the same withthe "Timing +" key.

4. Negative ion key
The function of negative ion is synchronized with the system,and can work independently.In working condition or standby state,touch the "negative ionkey to close its function; and touch the key again to start the function.

                                                                     6
 
5. Flow rate setting key
Through regulating valve knob to control the oxygen fow and concentration,the greater the flow,the smaller the oxygen concentration.

6.lnfrared remote control
The remote control key function is the same with control panel key function.

Remote Control Instructions

(1)On/0f key
(2)Timing + key
(3)Timing-key
(4)Negative ion key
(5)Sleep mode key

In working state, press "Sleep" mode key, the "Sleep" iconon the display screen will fash three times,then the screen will turn into sleep mode. Press any key on the remote control or touch any key on the machine panel to active the screen highlight.






Normal Operating Conditions

Operational temperature:5°C-40°C Relative humidity range:≤80%RH Atmospheric pressure range: 86kPa-106kPa

When the temperature is below 5°C,the machine should be put in normal operating condition for at least 4 hours before getting started.

Transport or storage conditions Storage temperature:-20°C-60°C Relative humidity range:≤93%RH

To avoid strong electromagnetic interference environment or interfering other domestic appliances, please keep the machine at least 3m away from other domestic appliances.

Symbols for safety requirement and meaning on the machine

Class ll equipment

                                                                7

Care and Maintenance

1. Cleaning housing unit
The surface of the housing should be cleaning at least once every month. Disconnect the power cord before you clean it. Wipe it with a clean, mild,damp cloth soaked with disinf-tant. Do not let the liquid penetrate into the machine.

2. Cleaning water tank
To keep the water tank clean,the water used should be purifed water, distilled water or cold boiled water.we suggest to change water every day.

The water tank should be cleaned every week. First use mild detergent and shake the tank to wash. Then use clean water to rinse it,

After cleaned the water tank, please remember to put water tank plastic plug back to avoid leakage of oxygen from the water inlet,caused no oxygen output from oxygen outlet mouth when the machine is in normal working.

3. Air flter cleaning
The white air flter at the back of the machine can reduce noise,isolate dust and purify the air. lt should be clean.lt should be cleaned around every ten days. First use mild detergent to wash,and then rinse it with clean water. Pay special attention that it must be dry to be positioned back, or the function of the molecular sieve could be damaged, which will lead to decreased oxygen concentration.
 
                                                                         8

4. Oxygen tube and oxygen inhaler cleaning In general condition,it should be cleaned every three days. The snorting part of nasal cannula should be cleaned after each use. You can soak it with 5% potassium permanganate solution for 5 minutes, then rinse with clean water, or wipe it with alcohol. Change a new oxygen tube every year.

5. Long-term storage operations

Before you long-term storage the oxygen concentrator, please do as follows:

1. Bring down the humidifer water tank, pull out the water,dry it and position it back.
2.Disconnect the power cord and put away the power cord .
3. Do not place plase the machine in damp, dusting environ-ment.
Avoid direct sunlight and pollution. Preserve the oxygen tube and oxygen inhaler at room temperature. Do not twist the airway tube. Keep out of the reach of the children.


Do as follows before restart the machine after long-termstorage
period:

1.Make sure the power cord is undamaged.
2.Clean the oxygen tube and oxygen inhaler. Check whether the tube is blocked or twisted. Please straighten out.
3.Clean the humidifer water tank.

                                                                        9

 Common Trouble-shooting

NO. Phenomenon Cause analysis Solution
1 Odor in air. In the initial stage of using, there is smell for the connection tube and other plastic parts. It is normal. The odor that comes from silicone tube and ABS rubber parts is normal and non-toxic by inspection. The odor will disappear as time goes by.
The humidifier water tank hasn't been cleaned for a long time or the water hasn't been changed. Clean the oxygen tube and humidifier water tank.
2 Water flows from the oxygen outlet. The water level of the humidifier water tank is beyond the highest water level, so the airflow pressed the bubble into the oxygen tube. Keep the water lower than the highest water level.
The machine has been used for a long time, so that the steam in the airflow gathers on the tube wall. Pour the water in water tank. And add water into the water tank when there is no water coming out from oxygen outlet.
3 The machine lets "puff" sound every several seconds It is the sound of nitrogen discharging which is normal and is a sign of fine working.
4 After startup, the machine operates well, the flowmeter displays "0" or is too small The flowmeter is off or the value is too small. Turn up the oxygen flow.
The oxygen tube is twisted or blocked. Straighten the oxygen tube.
The inner connection tube of the machine is disconnected or broken. Disconnect the power cord and contact professionals to repair it.

                                                                            10

5 After startup, there is bubble in the water tank, but there is no oxygen getting out from the oxygen outlet. The silica gel stopper of the humidifying water tank is not properly positioned. Remove the humidifying water tank to plug the silica gel stopper.
6 After startup, the indicator light works, but the machine does not (the sound is irregular). Compressor malfunction. Disconnect the power cord and contact professionals to repair it.
The temperature is so high that the self-protection mode of the oil-free compressor is activated. It is a normal case. When the temperature lowers down, the machine will restart automatically.
7 Separation valve malfunction. Disconnect the power cord and contact professionals to repair it.
The inner connection tube of the machine is disconnected or broken. Disconnect the power cord and contact professionals to repair it.

If it still does not work as you have followed the solutions listed above, do not disassemble the machine, Please consult the manufacturer for assistance.

                                                                      11

Operating Principle

The air comes into the compressor after compressed by air inlet flter unit and then it enters into molecular sieve tower to separate the oxygen and nitrogen. The oxygen successfully goes through the molecular sieve tower into the fne sieve tower. In contrast, the nitrogen is absorbed by the molecular, then to be discharged into the atmosphere through the separating valve. The oxygen concentration is enhanced in the fne sieve tower and controlled fow size by fowmeter. Then the oxygen is humidifed by the humidifying water tank when it comes to it. Finally, the oxygen reached the user through oxygen supply tube.

         

                                                                    12

CONTACT INFORMATION 

Website:    www.airoxygenconcentrator.com

Email:   support@airoxygenconcentrator.com

Tel/ Whatsapp: +86 18902540866

Help in need? Feel free to contact us